REARTH ® S Series (Compressed cryogenic condensation method)
Compressed Cryogenic
VOC recovery device of high condensation low air flow type using our unique compressed cryogenic condensation method An ideal device for recovery of extracting generated in chemical product purification and cleaning process. With a delivery record of over 500 units, recovery and recycling of VOC is well proven.   [Awarded, 1998 Annual City of Tokyo Industrial Technical Award] [Awarded, 1999 Chairman’s prize, JSIM 26th annual Excellent Environmental System Award]

[Selected, 2004 the Ministry of Environment empirical model business VOC treatment technology]

153
1: Applicable to wide range of solvent and use
  • Recovery of chlorinated solvent as well as solvent gas such as CFC substitutes
  • Flexibly supporting (support) even when the solvent is changed
2: Excellent economic benefit
  • High solvent recovery rate
  • Significant reduction in use volume of solvent
  • Recovered fluid is recyclable
  • Low running cost
3: Easy to setup
  • Compact design doesn’t take a space
  • Needing no wastewater treatment facility, drainage is only a small amount of separated water
  • Operable with just electricity and a small volume of cooling water

Flow chart

1. Suction ~ The suction from the VOC gas, such as washing machines and chemical products processors
2. Pre-cooling condenser ~ About minus 30 °C gas is discharged from the cryogenic condenser to pass through the cylinder,the gas is condensed and liquefied by heat exchange with the suction gas to pass through the outer tube.
3. Compressor ~ With the suction pressure by the compressor, it increases the concentration of the solvent on the apparent gas.
4. Water cooled condenser ~ With the supply of cooling water from an external source, pressured solvent gas is liquefied and condensed.
5. Cryogenic condenser ~ The gas is cooled by a refrigerator that cannot be liquefied by the water-cooled condenser. Almost all gases are liquefied here.
6-1. Active carbon unit (Absorption) ~ The activated carbon unit absorbs the gas which is several hundred to several thousand ppm could not be liquefied at cryogenic condenser.
-2. Active carbon unit (Desorption) ~ The solvent gas absorbed in the active carbon is desorbed with temperature (in the) pressure swing method using indirect heating and suction desorption
7. Condenser fluid tank ~ Solvent liquefied with water cooled condenser and cryogenic condenser is accumulated in the condenser fluid tank and regularly discharged to outside with the internal pressure.
8. Water separator ~ Water in the recovered solvent discharged from the condenser fluid tank is separated with water separator and recycled.